Részletek
ATTENTION! The rated voltage (Power 600 V, Signal 250 V) of the insert which is designed for basic insulation with protective grounding only applies if the shield of the data element is connected to the ground potential. When the shield of the data element is not connected to the ground potential, rated voltages will reduce to 320 V for Power and 150 V for Signal, rated impulse voltage 4 kV for Power and 2.5 kV for Signal.